Rockwell Automation Allen-Bradley PowerMonitor 1000 - Incorrect Access Control Authentication Bypass

Author: Luca.Chiou
type: webapps
platform: hardware
port: 80.0
date_added: 2018-12-04  
date_updated: 2018-12-04  
verified: 0  
codes: CVE-2018-19616  
tags: Authentication Bypass / Credentials Bypass (AB/CB)  
aliases:   
screenshot_url:   
application_url:   

raw file: 45937.txt  
# Exploit Title: Rockwell Automation Allen-Bradley PowerMonitor 1000 - Incorrect Access Control
# Date: 2018-11-27
# Exploit Author: Luca.Chiou
# Vendor Homepage: https://www.rockwellautomation.com/
# Version: 1408-EM3A-ENT B
# Tested on: It is a proprietary devices: https://ab.rockwellautomation.com/zh/Energy-Monitoring/1408-PowerMonitor-1000
# CVE : CVE-2018-19616

# 1. Description:
# In Rockwell Automation Allen-Bradley PowerMonitor 1000 web page, there are a few buttons are disabled,
# such as “Edit”, “Remove”, “AddNew”, “Change Policy Holder” and “Security Configuration”.
# View the source code of login page, those buttons/functions just use the “disabled” parameter to control the access right.
# It is allow attackers using proxy to erase the “disabled” parameter, and enable those buttons/functions.
# Once those buttons/functions are enabled.
# Attackers is capable to add a new user who have administrator right.